INSTALLATION INSTRUCTIONS
AND USER MANUAL
RESIDENTIAL USE ONLY
INSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 18 TO 21.
READ AND SAVE THESE INSTRUCTIONS
04313 rev. J
MODELS
VB0064
HEPA 3100*
HF 3.1*
HEPA 4100*
HRV 2600*
HR 2.6*
*Patents pending
NOTES: 1. HRV 2600* model is available in Canada only.
2. HEPA 4100* model is available in United States only.
Vedere la pagina 0
1 2 3 4 5 6 ... 21 22

Sommario

Pagina 1 - AND USER MANUAL

INSTALLATION INSTRUCTIONSAND USER MANUALRESIDENTIAL USE ONLYINSTALLER: LEAVE THIS MANUAL WITH THE HOMEOWNER.HOMEOWNER: USE AND CARE INFORMATION ON PAG

Pagina 2 - ABOUT THESE UNITS

7. Turn the unit switch knob to OFF position in order to unlock the door. Unlatch the door and open it. If required, the door can be removed. To do so

Pagina 3 - TABLE OF CONTENTS

5.2 HOW TO HANG THE UNITUse the 4 chains and springs in the hardware pack provided with the unit. According to your needs, you can install the unit ei

Pagina 4 - 1. TYPICAL INSTALLATIONS

- 12 -5.3 PLANNING OF THE DUCTWORKAll units in this manual are prebalanced.• Keep it simple. Plan for a minimum of bends and joints. • Keep the length

Pagina 5 - HEPA 4100 RESTRICTED AREA

5.4 INSTALLING NON-INSULATED DUCTS AND REGISTERS (CONT’D)5.4.1 STAND ALONE SYSTEM (AS ILLUSTRATED IN SECTION 1.1.1) (CONT’D)ALL UNITSHow to connect t

Pagina 6 - TTIC INSTALLATION

5.4 INSTALLING NON-INSULATED DUCTS AND REGISTERS (CONT’D)5.4.2 CENTRAL DRAW POINT (AS ILLUSTRATED IN SECTION 1.1.2) (CONT’D)Fresh/Filtered air ductwo

Pagina 7 - 2. DIMENSIONS

5.5 INSTALLING INSULATED FLEXIBLE DUCTSUse the following procedure for connecting the insulated flexible ducts to the Tandem® transition* (EXHAUST AIR

Pagina 8 - OCATING THE UNIT

5.5 INSTALLING INSULATED FLEXIBLE DUCTS (CONT’D)5.5.2 CONNECTION TO THE 5’’ TO 6’’ OVAL PORTS OF THE UNIT (CONT’D)4. Apply duct tape gently to the jo

Pagina 9 - 4. WALL CONTROL INSTALLATION

5.6 INSTALLING DUAL EXTERIOR HOOD (CONT’D)5.6.3 CONNECTING TANDEM® TRANSITION TO EXTERIOR DUAL HOOD (CONT’D)2. Join the end of the Tandem transition

Pagina 10

6.1 MAIN SWITCHAll units are equipped with a 3-position main switch, located on the front panel. 6.2 40415 AND 40425 WALL CONTROLS DESCRIPTIONThe incl

Pagina 11 - 5. INSTALL THE UNIT

6.4 WALL CONTROLS CONFIGURATIONSee the configuration table below for the list of configuration parameters. Press the Menu button for 3 seconds to ente

Pagina 12 - AND HR 2.6 UNITS ONLY

ABOUT THIS MANUALFirst, we want to congratulate you on your purchase of this excellent unit which will allow you and your family to enjoy clean and he

Pagina 13 - 5. INSTALL THE UNIT (CONT’D)

- 20 -7. MAINTENANCEWARNINGRisk of electrical shocks. Before performing any maintenance or servicing, always disconnect the unit from its power source

Pagina 14 - 3’ (0.9 m)

- 21 -7.1 BIANNUAL MAINTENANCE (ESSENTIAL) (CONT’D)6. Wash the 2 core filters under hot water with mild soap. Rinse thoroughly and let dry completely

Pagina 15 - XHAUST AIR TO OUTSIDE

If the problem is still not solved, call your installer or the nearest authorized Service Center. Also, you can reach the Customer Service Department

Pagina 16 - FRESH AIR FROM OUTSIDE

1. TYPICAL INSTALLATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-61.1 HR

Pagina 17

1. TYPICAL INSTALLATIONSInstallations may vary according to the model number and the position in which the unit is installed. Use the following illust

Pagina 18 - 6. CONTROLS

1. TYPICAL INSTALLATIONS (CONT’D)VH0043- 5 -1.1.3 RETURN-TO-RETURN INSTALLATION (CONNECTION TO A FORCED AIR SYSTEM)1.1 HRV 2600, HR 2.6, HEPA 3100, H

Pagina 19 - 6. CONTROLS (CONT’D)

All 3 types of installations can be used in the attic (Stand Alone, Central Draw Point or Return-Return). The example shown below is aReturn-Return in

Pagina 20 - 7. MAINTENANCE

- 7 -2.3 MOUNTING AND SERVICING CONSIDERATIONS• The two following pictures are showing the minimum clearance needed to open the door completely. 22.5”

Pagina 21 - 7. MAINTENANCE (CONT’D)

- 8 -3.3 LOCATING THE UNITChoose an appropriate location for the unit.• Within an area of the house where the ambient temperature is between 10°C (50°

Pagina 22 - 8. PARTS ORDERING CHART

- 9 -1. Route the cable from the unit to a convenient location for the wall control. 2. Loosen the locking screw (the screw cannot be completely remov

Commenti su questo manuale

Nessun commento